Industrial Temperature & Humidity Sensor (DIN Rail / RS-485)

Industrial temp & humidity sensor, RS-485 Modbus RTU or 4–20mA, IP65, ±0.3°C accuracy. DIN rail or wall-mount. CE/RoHS certified.

Specifikációk
Temperature range -40°C to +85°C (standard) / -60°C to +150°C (high temp)
Humidity range 0–100% RH (non-condensing)
Accuracy (temp) ±0.3°C at 25°C (±0.5°C across full range)
Accuracy (RH) ±2% RH at 25°C
Output 4–20mA (2-wire) or RS-485 Modbus RTU
Housing DIN rail (35mm) or wall-mount ABS enclosure
IP rating IP65 (NEMA 4 equivalent)
Tanúsítványok
CERoHSIP65

4–20mA vs. RS-485 Modbus: When to Use Each

4–20mA (current loop). A single analog signal carries temperature or humidity as a proportional current (4mA = range minimum, 20mA = range maximum). Immune to voltage drop over long cable runs (up to 300–500m). Simple wiring — two conductors for a 2-wire loop-powered sensor. Widely supported by existing PLC analog input cards. Limitation: one physical wire per measurement variable (temperature and humidity require two separate outputs or two 4–20mA channels).

RS-485 Modbus RTU. Digital bus protocol supports multiple sensors on a single 2-conductor twisted-pair cable (up to 32 nodes per segment, or more with repeaters). Each sensor reports temperature, humidity, and status registers over the Modbus address it is assigned. Requires a Modbus master (PLC, gateway, or DAQ system) to poll each device. Lower wiring cost for multi-sensor deployments; richer data (timestamps, alarm registers, sensor status codes) than 4–20mA.

Selection criteria:

  • Legacy PLC analog input cards: use 4–20mA
  • New installation with >5 sensors on a common bus: RS-485 Modbus reduces wiring costs significantly
  • Long cable runs (>100m) in noisy electrical environments: both are adequate, but Modbus with proper shielding is more tolerant of voltage spikes

IP65 vs. IP67 Gland Sealing

IP65 certifies protection against dust ingress and directed water jets (12.5 L/min from any direction). IP67 adds 30-minute submersion to 1 meter. For most industrial HVAC, cold storage, and outdoor enclosure applications, IP65 is sufficient.

The weak point in IP-rated sensor enclosures is the cable gland. Confirm:

  • Cable gland material: brass (preferred for industrial) vs. plastic (adequate for light duty)
  • Gland size matches your installation cable OD — a mismatched gland defeats the IP rating regardless of enclosure sealing
  • Conduit entry threads: M16, M20, or PG-11 are common DIN rail sensor thread sizes

For food processing or wash-down environments where the sensor will be directly sprayed: specify IP67 or IP69K (high-pressure water jet resistance), not IP65.

Calibration Certificate Traceability

Sensors used in process control, energy management systems, or regulated environments may require calibration traceability to national standards. Ask the factory:

  1. Is a calibration certificate included? Basic sensors ship with a QC test report (factory internal), not a third-party calibration certificate. These are acceptable for HVAC and building automation.

  2. NIST or ISO 17025 traceable calibration. For pharmaceutical cold chain, clean room monitoring, or ISO 9001 audit-compliant processes, the sensor calibration must be traceable to NIST (US) or the national metrological standard of the country of use. This requires calibration at a CNAS (China) or ISO 17025 accredited lab — adds $15–40 per sensor and 3–5 days to lead time.

  3. Sensor element type. Most industrial T&H sensors use either a capacitive sensing element (Sensirion SHT series or equivalent) or a thermistor + capacitive humidity element. Ask for the sensing element part number — it determines drift characteristics and replacement availability if the element degrades.

Long-Term Drift Specification

Humidity sensors drift over time due to contamination, chemical exposure, and aging of the capacitive polymer film. A well-specified sensor should state:

  • Drift rate: typically <±0.5% RH per year under normal conditions
  • Recovery from high humidity exposure (100% RH for extended periods): some sensors require a “reconditioning” bake at 100°C for 1 hour to restore accuracy after prolonged saturation
  • Chemical resistance: common industrial contaminants (solvents, cleaning agents, H2S, ammonia) degrade certain sensing elements faster than others

For long-term outdoor or harsh environment installations, sensors with replaceable sensing cartridges reduce total cost of ownership compared to replacing the full sensor unit.